Tripp Lite In-Row Precision Cooling System – 12 kW (41,000 BTU/hr), 208-240V, 42U, 300mm – Indoor In-row Air Conditioning Unit for Server Rooms 12 KW 41 000 BTU 208-240V 42U

Tripp Lite In-Row Precision Cooling System – 12 kW (41,000 BTU/hr), 208-240V, 42U, 300mm – Indoor In-row Air Conditioning Unit for Server Rooms 12 KW 41 000 BTU 208-240V 42U

VPN: SRCOOLDXRW12 UPC: 37332250674 SKU: 00HT47

$24,001.20

IN-ROW PRECISION COOLING SYSTEM 12 KW 41 000 BTU 208-240V 42U

Share:

Miscellaneous
Additional Information

    INPUT

    • Electrical Consumption (Max) : 4.8 kW
    • Nominal Input Voltage(s) Supported : 208V AC; 240V AC
    • Maximum Input Amps : 16
    • Input Connection Type : 3-wire / 4-wire + Ground
    • Input Frequency : 50/60 Hz

    COOLING

    • Cooling Type : Active
    • Airflow : 1,475 CFM
    • Cooling Capacity (BTUs) : 43,686
    • Cooling Capacity (kW) : 12.8

    USER INTERFACE, ALERTS & CONTROLS

    • Front Panel LEDs: 7-inch color touchscreen

    ENVIRONMENTAL

    • Storage Temperature Range : -40 to 140 degF
    • Operating Elevation (ft.) : 0 to 13,000
    • Operating Temperature : 4 to 115 degF
    • Operating Humidity Range : 5 to 80%
    • Ambient Operation RH : 5 to 80%
    • Condensate Drain Pumps (L/HR) : Max distance 150ft (45m), max lift 26.5ft (8m)
    • Condensate Water Drains : 1/4 in. Connection

    FEATURES & SPECIFICATIONS

    • Compressor Type : Rotary (Inverter Driven)
    • Refrigerant : R410a (Environmentally friendly, Non ozone depleting)
    • Refrigerant Amount : 12.1 lb. / 5.0 kg (Nominal)
    • Sound Level (Noise) : 78 DBA @ 1475 CFM @ 1 METER
    • Fans (Type/Quantity) : 0-2000 RPM x 3

    OPERATION

    • Operation Mode : Cooling, Standby, Off, Maintenance Mode
    • Supply Air Temperature (Celsius) : 18-27 deg. C (limited by heating load)
    • Applied Containment Types : Close/Open
    • Fan Controls : Automatic
    • Force Modes : Maintenance Mode, Rotation Mode
    • Installation Modes : Condenser above or slightly below In-Row; vertical condenser.
    • Manual Modes : Service and factory setting menus for manual adjustment
    • Power Redundancies : Single only
    • System Type Selections : Deg. F; Deg. C (default is Deg. F)
    • Temperature Unit Selections : Deg. F; Deg. C (default is Deg. F)

    STANDARDS & COMPLIANCE

    Application/UsageServer
    Package Contents
    • Indoor In-row Air Conditioning Unit
    • Outdoor Condenser
    • Side Discharge Panels / Adapters
    • Hardware Kits
    • Owner's Manual
    Country of OriginChina
    Environmentally FriendlyYes
    Environmental CertificationRoHS
    General Information
    Product TypeCooling System
    Manufacturer Part NumberSRCOOLDXRW12
    Manufacturer Website Addresshttp://www.tripplite.com
    ManufacturerTripp Lite by Eaton
    Product ModelSRCOOLDXRW12
    Product NameIndoor In-row Air Conditioning Unit
    Brand NameTripp Lite
    Physical Characteristics
    Weight (Approximate)397 lb
    Height78.7"
    Width11.8"
    Depth43.3"
    Product ColorBlack
    Product MaterialAluminum
    Steel

    Tripp Lite In-Row Precision Cooling System – 12 kW (41,000 BTU/hr), 208-240V, 42U, 300mm – Indoor In-row Air Conditioning Unit for Server Rooms 12 KW 41 000 BTU 208-240V 42U
    Slim Air Conditioning System Saves Space While Delivering Primary Precision CoolingThis SmartRack® in-row precision air conditioning system is the ideal cooling option for your small-to-medium data center, IT room or other edge location. Typical CRAC/CRHC units are too large for these locations, but the SRCOOLDXRW12 cools your mission-critical equipment while occupying very little floor space, supporting up to 12.8kW (43,686 BTU/hr) of heat load per unit. The cabinet is just 300 millimeters wide, making it easy to position optimally within a row for precision close-coupled cooling. It requires the same front and rear clearance as a standard rack enclosure. Uses DX Technology to Deliver Cool Air to LoadsThis direct expansion (DX) cooling system pulls unconditioned air through the rear of the unit, cools it with condensed refrigerant and delivers it to equipment loads with up to 43,686 BTU/hour and more than 1,475 CFM airflow. EC fans and a variable speed compressor provide variable airflow and constant temperature based on room conditions. High Cooling Efficiency Saves You MoneyInverter compressor and EC fan technology automatically regulate cooling output to match heat load and conserve energy during off-peak hours, lowering your overall energy costs and lengthening the lifespan of the equipment being cooled. The close-coupled design captures heat at the source to improve energy efficiency by 25% over traditional perimeter CRACs. In addition, the SRCOOLDXRW12 is ideally sized for your small-to-medium data center at virtually any density, saving you the cost of a raised floor or an overbuilt/overprovisioned CRAC unit. It uses eco-friendly R410A refrigerant, reflecting your commitment to environmental responsibility. Easy to Operate with the Color TouchscreenYou have total control over the SRCOOLDXRW12 using the front-panel color touchscreen interface, which lets you monitor and access system configuration and status information. A built-in controller detects and manages data center temperatures, automatically adjusts cooling levels and supports various control modes. Intelligent temperature control and variable speed technology allow precise airflow and temperature adjustment to match specific load requirements closely without wasting energy on overcooling. Reconfigure Your Cooling Needs as Your Equipment Needs ChangeThe modular, in-row cabinet design easily facilitates expansion or movement on its built-in casters, allowing your increasing cooling needs to be reconfigured as your data center grows. A simple redundancy model (N+1) is built in as part of the number of scalable units to be deployed. Pre-Installed WEBCARDLXMINI Network Interface Offers 24/7 AccessRemote access to the SRCOOLDXRW12 can save you the time and expense of having someone constantly on-site. The built-in WEBCARDLXMINI lets you manage temperatures, receive alerts, review logs and control settings 24/7 via HTTP(S), menu/CLI via SSH/Telnet and SNMP for integration with management software platforms such as DCIM. The ability to configure settings and monitor alarms off-site can bolster your bottom line.

    Tripp%20Lite SRCOOLDXRW12

    Features

    Cools mission-critical equipment with up to 12.8 kW (43,686 BTU/hr) of high-precision in-row cooling power

    Slim 300 mm profile allows maximum cooling while taking up little space

    Close-coupled design improves energy efficiency by 25% over traditional CRACs

    User-friendly color touchscreen allows complete access to data and status information

    Configurable side and/or front airflow discharge and maintenance mode capability

    1-year limited warranty