C2G 50ft HDBaseT Certified Cat6a Cable – Non-Continuous Shielding – CMP Plenum – 50 ft Category 6a Network Cable for Network Device – First End: 1 x RJ-45 Network – Male – Second End: 1 x RJ-45 Network – Male – 10 Gbit/s – Patch Cable – Shielding – Gold Plated Contact – 23 AWG – Blue

C2G 50ft HDBaseT Certified Cat6a Cable – Non-Continuous Shielding – CMP Plenum – 50 ft Category 6a Network Cable for Network Device – First End: 1 x RJ-45 Network – Male – Second End: 1 x RJ-45 Network – Male – 10 Gbit/s – Patch Cable – Shielding – Gold Plated Contact – 23 AWG – Blue

VPN: 43172 UPC: 757120431725 SKU: 1FB557

$251.99

50FT CAT6A HDBASET CABLE PLENUM

SKU: ed655a3ee593 Categories: , ,

Share:

Physical Characteristics
Weight (Approximate)1.77 lb
Product ColorBlue
Technical Information
Cable Length50 ft
Data Transfer Rate10 Gbit/s
Device SupportedNetwork Device
ShieldingYes
FeaturesMolded
PoE
Crosstalk Protection
Cable CharacteristicPatch Cable
Cable TypeCategory 6a
Connector Type on First EndRJ-45 Network - Male
Connector Type on Second EndRJ-45 Network - Male
American Wire Gauge23 AWG
Contact PlatingGold
Connector on First End Details1 x RJ-45 Network - Male
Connector on Second End Details1 x RJ-45 Network - Male
General Information
Product TypeNetwork Cable
Manufacturer Part Number43172
Manufacturer Website Addresshttp://www.cablestogo.com
ManufacturerC2G
Product Name50ft HDBaseT Certified Cat6a Cable - Non-Continuous Shielding - CMP Plenum
Brand NameC2G
Miscellaneous
Country of OriginUnited States
Environmentally FriendlyYes
Environmental CertificationREACH
RoHS
RoHS 2
Energy StarYes

C2G 50ft HDBaseT Certified Cat6a Cable – Non-Continuous Shielding – CMP Plenum – 50 ft Category 6a Network Cable for Network Device – First End: 1 x RJ-45 Network – Male – Second End: 1 x RJ-45 Network – Male – 10 Gbit/s – Patch Cable – Shielding – Gold Plated Contact – 23 AWG – Blue
This Snag Discontinuous Shielded Cat6a patch cable is ideal for use with HD A/V applications such as HDBaseT extenders and Power over Ethernet (PoE) applications requiring higher levels of current. The HD A/V application is perfect for conference rooms and digital signage where greater distance requirements are needed between a source and a display. Each patch cable is fully tested to meet ANSI/TIA 568 C.2 Cat6a channel requirements.These cables have been tested and validated to guarantee they consistently meet the highest industry performance and safety standards. The uniquely designed Isolation Wrap contains discontinuous sections of metallized material, held in place by a polymeric layer. These cables have a nominal 0.265″ diameter that allows for higher cable density and smaller bend radius than other Cat6a cable products. These cables are also designed for Power over Ethernet (PoE) applications type 1-4 according to IEEE 802.3bt draft D1.2.These cables have discontinuous metallic shielding elements surrounding the inner 4-pair core of the cable. The effect of this approach is to attenuate both electromagnetic signals that emanate from the cable core and the potentially interfering electromagnetic signals that are generated by other sources. The metallic shielding elements are designed to be discontinuous to avoid any need for grounding, which is a requirement for shielded cable designs, and have been shown to provide superior Alien Crosstalk performance in comparison to conventionally designed Category 6A UTP cables.

C2g 43172

Features

Discontinuous shielding avoids need for grounding

HDBaseT Class A and B certified

Designed to support up to 10 Gigabit data transmission

Snag design for high density applications

X