Tripp Lite 250W Isolation Transformer Hospital Medical with Surge 120V 2 Outlet HG TAA GSA – 250W – 120V AC – 120V AC 120V MEDICAL GRADE 2 OUT UL60601-1

Tripp Lite 250W Isolation Transformer Hospital Medical with Surge 120V 2 Outlet HG TAA GSA – 250W – 120V AC – 120V AC 120V MEDICAL GRADE 2 OUT UL60601-1

VPN: IS250HG UPC: 37332116208 SKU: C77199

$390.00

250W HG ISOLATION TRANSFORMER 120V MEDICAL GRADE 2 OUT UL60601-1

Share:

Technical Information
Power Rating250 VA
Output Receptacle Detail2 x NEMA 5-15R
Output Receptacle TypeNEMA 5-15R
Physical Characteristics
Form FactorTower
Height4.5"
Width4.8"
Depth7.8"
Miscellaneous
Additional Information
    • Transformer Type: Medical grade, low impedance transformer-based line isolation transformer
    • Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops
    • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
    • Suppression Joule Rating: 680 (510 input/170 output)
    • Leakage Current: As low as 100 microamps
    • Noise Suppression Rating: 35 to 65 DB
    • Total Harmonic Distortion: than 1%
    • Over Current Protection: 2A circuit breaker
    • Cooling Method: Convection
    • Efficiency: 96%
    • Let-through Voltage (Ring Wave):
    • L-N: 20 V
    • L-G: 20 V
    • N-G: 0.5 V
    • Let-through Voltage (Combination Wave):
    • L-N: 250 V
    • L-G: 250 V
    • N-G: 0.5 V
Package Contents
  • IS250HG
  • IS250HG Isolation Transformer
  • Instruction manual with warranty information
Certifications & Standards
    • cUL
    • UL 2601-1
    • UL (UL Series AGIS250YWN)
Country of OriginTaiwan
TAA CompliantYes
Power Description
Input Voltage120 V AC
120 V AC
Output Voltage120 V AC
120 V AC
Maximum Line Current2.10 A
General Information
Product TypeIsolation Transformer
Manufacturer Part NumberIS250HG
Manufacturer Website Addresshttp://www.tripplite.com
ManufacturerTripp Lite by Eaton
Product ModelIS250HG
Product NameIsolator IS250HG Isolation Transformer
Brand NameTripp Lite

Tripp Lite 250W Isolation Transformer Hospital Medical with Surge 120V 2 Outlet HG TAA GSA – 250W – 120V AC – 120V AC 120V MEDICAL GRADE 2 OUT UL60601-1
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harm levels. Reduces 6000V IEE

Tripp%20Lite IS250HG

Features

Complete line isolation, noise filtering and surge suppression; ideal for sensitive equipment

250 watts, 2 outlets, 6-ft. power cord

Hospital-grade plug and receptacles

Leakage current than 100 microamps

Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

X