Tripp Lite PDU Metered 16 C13 4 C19 3.2/3.8kW 208/240V C20/L6-20P 10ft Cord – Metered – NEMA L6-20P, IEC 60320 C20 – 16 x IEC 60320 C13, 4 x IEC 60320 C19 – 230 V AC – 0U – Vertical/Tool – Rack-mountable, Wall-mountable 240V 3.2/3.8KW C20/L6-20P 10FT CORD
Single-Phase PDU Distributes and Monitors Network-Grade Power in Real TimeThis metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMV20HV-36 features 16 C13 and four C19 200-240V outlets for connecting equipment. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged. The switch design helps prevent an accidental shutdown, which could lead to costly downtime. Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Versatile Installation Options Give You Plenty of ChoicesThe 40-inch 0U PDU mounts vertically in an EIA-standard 19-inch rack using the included tool mounting buttons or the included mounting brackets with user-supplied hardware. You may also use the brackets to secure the PDU to the underside of a counter with the addition of two user-supplied screws. Bolt-down retention brackets keep power cords organized and your rack free of clutter. Compatible with a Variety of Input Cords to Fit Your Facility’s Power SourceThe PDU’s C20 inlet accepts a variety of 16A international cordsets. An included 10-ft. (3.05 m) cord with NEMA L6-20P input plug connects to an AC power source, generator or protected UPS system to distribute power to connected loads.
Tripp%20Lite PDUMV20HV-36
Features
16 C13 and 4 C19 200-240V outlets distribute AC power to connected equipment
Digital ammeter for on-site real-time load monitoring helps prevent power overloads
Switch design helps prevent accidental shutdowns that can lead to costly downtime
10-ft. (3.05 m) detachable cord with L6-20P single-phase input connects to AC power source
40 in. 0U PDU with included mounting brackets installs in rack or under counter
2-year limited warranty